MULTIQUIP RX 1510-I Instruções de Operação Página 64

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 63
RX 1510-C/-I/-CI
– 64 –
SI
SM
NOTE
The addresses at the transmitter and receiver must correspond.Transmitter and
receiver are factory set to address 5.
(only for machines with infrared control)
Setting the transmitter address on the machine controller:
1) Fold the operating panel back.
2) Remove the plug
SM
from the machine controller with a screwdriver
entfernen.
3) Set in the required address by turning the arrow with a screwdriver.
Setting the transmitter address on the infrared control:
Remove the plug „SI“ from the infrared control with a screwdriver entfernen.
Set the same address as on the machine controller by turning the arrow with
a screwdriver.