GENERATOR OUTPUTS

A wide range of voltages are available to supply voltage for
many different applications. Voltages are selected by using
the voltage selector switch (Figure 12). To obtain some of
the voltages as listed in Table 7 (see below) will require a
fine adjustment using the voltage regulator (VR) control
knob located on the control panel.

The voltage selector switch (Figure 12) is located above
the output terminal panel’s Hard Wire Hook-up Panel. It
has been provided for ease of voltage selection..
Figure 12. Voltage Selector Switch
CAUTION
 change the position of the voltage selector
Switch while the engine is running.  place
circuit breaker in the OFF position before selecting
voltage








208V 220V 240V 416V 440V 480V
 120V 127V 139V 240V 254V 277V



120V
Line-Neutral
N/A N/A
240V
Line-Line
N/A N/A

Table 8 shows the maximum amps the generator can
provide. DO NOT exceed the maximum amps as listed.

The load capability of the GFCI receptacles is directly
related to the voltage being supplied at either the output
terminals or the three twist lock auxiliary receptacles.
Figure 15 and Table 10 show what amount of current is
available at the GFCI receptacles when the output terminals
and twist lock receptacles are in use. Be careful that your
load does not to exceed the available current capability at
the receptacles.

 
120 Volt
100 amps (4 wire)
108 amps X 2 (Zigzag)
240 Volt
50 amps (4 wire)
108 amps (Zigzag)
240 Volt 108 amps
480 Volt 54 amps

KW in Use



1Ø 240/120V
GFCI Duplex
5-20R 120V
26 0
24.8 5 amps/receptacle
23.6 10 amps/receptacle
22.4 15 amps/receptacle
21.2 20 amps/receptacle





3Ø 240/480V
GFCI Duplex
5-20R 120V
45
0 amps/receptacle
40.9
5 amps/receptacle
36.7
10 amps/receptacle
32.6
15 amps/receptacle
28.4
20 amps/receptacle